Page 1 of126 Audix Technology Corporation. Report No.: EM-E960238 EMC TEST REPORT for DIVA Laboratories Ltd. LCD Monitor Models No.: ER-192 Br
Page 10 of126 Audix Technology Corporation. Report No.: EM-E960238 2.2.5. USB 2.0 STORAGE MEDIA Model Number : USM64U2 Serial Number : N/A FCC I
Page 100 of126 Audix Technology Corporation. Report No.: EM-E960238 Voltage Dips And Interruptions Immunity Test Results AUDIX TECHNOLOGY CORPORATION
Page 101 of126 Audix Technology Corporation. Report No.: EM-E960238 14. PHOTOGRAPHS 14.1. Photos of Conducted Disturbance Measurement Test Mode: EUT
Page 102 of126 Audix Technology Corporation. Report No.: EM-E960238 Test Mode: EUT with LINE Electronics AC Adapter (M/N LE-0312B130W) FRONT VIEW
Page 103 of126 Audix Technology Corporation. Report No.: EM-E960238 14.2. Photos of Radiated Disturbance Measurement at Semi-Anechoic Chamber Test M
Page 104 of126 Audix Technology Corporation. Report No.: EM-E960238 Test Mode: EUT with LINE Electronics AC Adapter (M/N LE-0312B130W) FRONT VIEW
Page 105 of126 Audix Technology Corporation. Report No.: EM-E960238 14.3. Photos of Radiated Disturbance Measurement at Open Area Test Site Test Mode
Page 106 of126 Audix Technology Corporation. Report No.: EM-E960238 SETUP WITH MAXIMUM DETECTED EMISSION AT HORIZONTAL POLARIZATION SETUP WITH
Page 107 of126 Audix Technology Corporation. Report No.: EM-E960238 Test Mode: EUT with LINE Electronics AC Adapter (M/N LE-0312B130W), D-Sub Input
Page 108 of126 Audix Technology Corporation. Report No.: EM-E960238 SETUP WITH MAXIMUM DETECTED EMISSION AT HORIZONTAL POLARIZATION SETUP WITH
Page 109 of126 Audix Technology Corporation. Report No.: EM-E960238 14.4.Photos of Discontinuous Disturbance Emission Measurement Test Mode: EUT with
Page 11 of126 Audix Technology Corporation. Report No.: EM-E960238 2.2.11. SIGNAL GENERATOR (Link to EUT) Model Number : LT443D Serial Number : D
Page 110 of126 Audix Technology Corporation. Report No.: EM-E960238 Test Mode: EUT with LINE Electronics AC Adapter (M/N LE-0312B130W) FRONT VIEW
Page 111 of126 Audix Technology Corporation. Report No.: EM-E960238 14.5. Photos of Harmonic and Voltage Fluctuations/Flicker Emission Measurement Te
Page 112 of126 Audix Technology Corporation. Report No.: EM-E960238 14.6. Photos of Electrostatic Discharge Immunity Test Test Mode: EUT with AULT AC
Page 113 of126 Audix Technology Corporation. Report No.: EM-E960238 Test Mode: EUT with LINE Electronics AC Adapter (M/N LE-0312B130W) Air & C
Page 114 of126 Audix Technology Corporation. Report No.: EM-E960238 Photo of ESD Test Points (Front View) Photo of ESD Test Points (Back View)
Page 115 of126 Audix Technology Corporation. Report No.: EM-E960238 Photo of ESD Test Points (I/O Ports)
Page 116 of126 Audix Technology Corporation. Report No.: EM-E960238 14.7. Photos of RF Field Strength Immunity Test Test Mode: EUT with AULT AC Adapt
Page 117 of126 Audix Technology Corporation. Report No.: EM-E960238 Test Mode: EUT with AULT AC Adapter (M/N MW116) Frequency Range: 1~2.5GHz FRON
Page 118 of126 Audix Technology Corporation. Report No.: EM-E960238 Test Mode: EUT with LINE Electronics AC Adapter (M/N LE-0312B130W) Frequency Ra
Page 119 of126 Audix Technology Corporation. Report No.: EM-E960238 Test Mode: EUT with LINE Electronics AC Adapter (M/N LE-0312B130W) Frequency Ra
Page 12 of126 Audix Technology Corporation. Report No.: EM-E960238 2.2.16. TRINITRON COLOR VIDEO MONITOR (Link to EUT) Model Number : PVM-14L2 Ser
Page 120 of126 Audix Technology Corporation. Report No.: EM-E960238 14.8. Photos of Electrical Fast Transient/Burst Immunity Test Test Mode: EUT with
Page 121 of126 Audix Technology Corporation. Report No.: EM-E960238 14.9. Photos of Surge Immunity Test Test Mode: EUT with AULT AC Adapter (M/N MW11
Page 122 of126 Audix Technology Corporation. Report No.: EM-E960238 14.10.Photos of Conducted Disturbance Immunity Test Test Mode: EUT with AULT AC A
Page 123 of126 Audix Technology Corporation. Report No.: EM-E960238 Test Mode: EUT with AULT AC Adapter (M/N MW116) Injection Position: I/O Cable (
Page 124 of126 Audix Technology Corporation. Report No.: EM-E960238 Test Mode: EUT with LINE Electronics AC Adapter (M/N LE-0312B130W) Injection Po
Page 125 of126 Audix Technology Corporation. Report No.: EM-E960238 14.11.Photos of Power Frequency Magnetic Field Immunity Test Test Mode: EUT with
Page 126 of126 Audix Technology Corporation. Report No.: EM-E960238 14.12.Photos of Voltage Dips and Interruptions Immunity Test Test Mode: EUT with
APPENDIX Audix Technology Corporation. Report No.: EM-E960238 APPENDIX (Photos of EUT) Total Pages: 21 Pages
APPENDIX - 1 of 21 Audix Corporation. Report No.: EM-E960238 Figure 1 General Appearance (Front View) Figure 2 General Appearance (Front & Sid
APPENDIX - 2 of 21 Audix Corporation. Report No.: EM-E960238 Figure 3 General Appearance (Rear View) Figure 4 General Appearance (Rear & Side
Page 13 of126 Audix Technology Corporation. Report No.: EM-E960238 NVLAP Lab. Code : 200077-0 (NVLAP is a NATA accredited body under Mutual Recogn
APPENDIX - 3 of 21 Audix Corporation. Report No.: EM-E960238 Figure 5 General Appearance (Bottom View) Figure 6 Appearance (I/O Ports)
APPENDIX - 4 of 21 Audix Corporation. Report No.: EM-E960238 Figure 7 Internal View (Removed Back Cover) Figure 8 Internal View
APPENDIX - 5 of 21 Audix Corporation. Report No.: EM-E960238 Figure 9 Internal View (Removed Main Board & Power Board) Figure 10 Internal View
APPENDIX - 6 of 21 Audix Corporation. Report No.: EM-E960238 Figure 11 Internal View (Power Board/Foil View) Figure 12 Internal View (Main Board/C
APPENDIX - 7 of 21 Audix Corporation. Report No.: EM-E960238 Figure 13 Internal View (Main Board/Foil View) Figure 14 Internal View (Inverter Boar
APPENDIX - 8 of 21 Audix Corporation. Report No.: EM-E960238 Figure 15 Internal View (Inverter Board/Foil View) Figure 16 Internal View (LCD Panel
APPENDIX - 9 of 21 Audix Corporation. Report No.: EM-E960238 Figure 17 Internal View (LCD Panel/Rear View) Figure 18 Internal View (Function Contr
APPENDIX - 10 of 21 Audix Corporation. Report No.: EM-E960238 Figure 19 Internal View (Function Control Board/Foil View) Figure 20 Internal View (
APPENDIX - 11 of 21 Audix Corporation. Report No.: EM-E960238 Figure 21 Internal View (Control Board of LCD Panel/Component View) Figure 22 Intern
APPENDIX - 12 of 21 Audix Corporation. Report No.: EM-E960238 Figure 23 Internal View (Control Board of LCD Panel/Component View) Figure 24 Intern
Page 14 of126 Audix Technology Corporation. Report No.: EM-E960238 3. CONDUCTED DISTURBANCE MEASUREMENT 3.1. Test Equipment The following test equi
APPENDIX - 13 of 21 Audix Corporation. Report No.: EM-E960238 Figure 25 D-Sub Data Cable Figure 26 DVI Data Cable
APPENDIX - 14 of 21 Audix Corporation. Report No.: EM-E960238 Figure 27 BNC Data Cable Figure 28 AC Adapter :AULT, M/N MW116 General Appearance (F
APPENDIX - 15 of 21 Audix Corporation. Report No.: EM-E960238 Figure 29 AC Adapter :AULT, M/N MW116 General Appearance (Rear & Side View) Figur
APPENDIX - 16 of 21 Audix Corporation. Report No.: EM-E960238 Figure 31 AC Adapter :AULT, M/N MW116 Internal View (Removed Covers) Figure 32 AC Ada
APPENDIX - 17 of 21 Audix Corporation. Report No.: EM-E960238 Figure 33 AC Adapter :AULT, M/N MW116 Internal View (PCB/Foil View) Figure 34 AC Adap
APPENDIX - 18 of 21 Audix Corporation. Report No.: EM-E960238 Figure 35 AC Adapter : LINE Electronics, M/N LE-0312B130W General Appearance (Rear &
APPENDIX - 19 of 21 Audix Corporation. Report No.: EM-E960238 Figure 37 AC Adapter : LINE Electronics, M/N LE-0312B130W Internal View (Removed Covers
APPENDIX - 20 of 21 Audix Corporation. Report No.: EM-E960238 Figure 39 AC Adapter : LINE Electronics, M/N LE-0312B130W Internal View (PCB/Component
APPENDIX - 21 of 21 Audix Corporation. Report No.: EM-E960238 Figure 41 AC Adapter : LINE Electronics, M/N LE-0312B130W Internal View (PCB/Foil View)
Page 15 of126 Audix Technology Corporation. Report No.: EM-E960238 3.4. EUT’s Configuration during Compliance Measurement The following equipments w
Page 16 of126 Audix Technology Corporation. Report No.: EM-E960238 3.5.6. Signal Generator sent the “Color Bar” image to LCD Monitor (EUT), then t
Page 17 of126 Audix Technology Corporation. Report No.: EM-E960238 3.7. Conducted Disturbance Voltage Measurement Results PASSED. (All emissions
Page 18 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 19 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 2 of126 Audix Technology Corporation. Report No.: EM-E960238 TABLE OF CONTENTS Description Page TEST REPORT VERIFICATION...
Page 20 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 21 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 22 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 23 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 24 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 25 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 26 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 27 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 28 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 29 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 3 of126 Audix Technology Corporation. Report No.: EM-E960238 8.3. Test Standard ...
Page 30 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 31 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 32 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 33 of126 Audix Technology Corporation. Report No.: EM-E960238 4. RADIATED DISTURBANCE MEASUREMENT 4.1. Test Equipment The following test equip
Page 34 of126 Audix Technology Corporation. Report No.: EM-E960238 4.2.2. Semi-Anechoic Chamber (3m) & Open Area Test Site (10m) Setup Diagram
Page 35 of126 Audix Technology Corporation. Report No.: EM-E960238 4.6. Test Procedure The EUT was placed on a turn table which was 0.8 meter above
Page 36 of126 Audix Technology Corporation. Report No.: EM-E960238 Finally, selected the worst test modes (Mode 2、11) were measured at No. 6 open a
Page 37 of126 Audix Technology Corporation. Report No.: EM-E960238 4.7.1. Radiated Disturbance Measurement Results at Semi-Anechoic Chamber
Page 38 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 39 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 4 of126 Audix Technology Corporation. Report No.: EM-E960238 14.8. Photos of Electrical Fast Transient/Burst Immunity Test...
Page 40 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 41 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 42 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 43 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 44 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 45 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 46 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 47 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 48 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 49 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 5 of126 Audix Technology Corporation. Report No.: EM-E960238 TEST REPORT VERIFICATION Applicant : DIVA Laboratories Ltd. Manufacturer :
Page 50 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 51 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 52 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 53 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 54 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 55 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 56 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 57 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 58 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 59 of126 Audix Technology Corporation. Report No.: EM-E960238 4.7.2. Radiated Disturbance Measurement Results at No. 6 Open Area Test Site 3.
Page 6 of126 Audix Technology Corporation. Report No.: EM-E960238 1. SUMMARY OF STANDARDS AND RESULTS 1.1. Description of Standards and Results The
Page 60 of126 Audix Technology Corporation. Report No.: EM-E960238 3. The worst emission is detected at 37.755MHz with corrected signal level of 25.
Page 61 of126 Audix Technology Corporation. Report No.: EM-E960238 3. The worst emission is detected at 36.383MHz with corrected signal level of 26.
Page 62 of126 Audix Technology Corporation. Report No.: EM-E960238 3. The worst emission is detected at 36.388MHz with corrected signal level of 26.
Page 63 of126 Audix Technology Corporation. Report No.: EM-E960238 5. DISCONTINUOUS DISTURBANCE EMISSION MEASUREMENT 5.1. Test Equipment The follow
Page 64 of126 Audix Technology Corporation. Report No.: EM-E960238 5.3. Limits for Discontinuous Disturbance 5.3.1. Click Limit (EN55014-1) Frequenc
Page 65 of126 Audix Technology Corporation. Report No.: EM-E960238 5.6. Test Procedure 5.6.1. The EUT to be measured is connected to an Artificial
Page 66 of126 Audix Technology Corporation. Report No.: EM-E960238 5.7. Measurement Results 5.7.1. For frequency 150kHz Date of Test: Aug. 24, 2007
Page 67 of126 Audix Technology Corporation. Report No.: EM-E960238 Date of Test: Aug. 24, 2007 Temperature: 26℃ EUT: LCD Monitor Humidity: 57% Test
Page 68 of126 Audix Technology Corporation. Report No.: EM-E960238 6. POWER HARMONICS AND FLICKER MEASUREMENT 6.1. Test Equipment Item Type Manuf
Page 69 of126 Audix Technology Corporation. Report No.: EM-E960238 6.5. Operating Condition of EUT Same as conducted measurement which was listed in
Page 7 of126 Audix Technology Corporation. Report No.: EM-E960238 1.2. Description of Compliance Criteria The equipment or system shall be able to p
Page 70 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 71 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 72 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 73 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 74 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 75 of126 Audix Technology Corporation. Report No.: EM-E960238
Page 76 of126 Audix Technology Corporation. Report No.: EM-E960238 7. ELECTROSTATIC DISCHARGE IMMUNITY TEST 7.1. Test Equipment Item Type Manufac
Page 77 of126 Audix Technology Corporation. Report No.: EM-E960238 7.3. Test Standard EN 60601-1-2/2001+A1/2006 (IEC 61000-4-2/2001) 7.4. Severity
Page 78 of126 Audix Technology Corporation. Report No.: EM-E960238 7.8. Test Results PASSED. EUT with following test modes were performed during thi
Page 79 of126 Audix Technology Corporation. Report No.: EM-E960238 Electrostatic Discharge Immunity Test Results AUDIX TECHNOLOGY CORPORATION Date:09
Page 8 of126 Audix Technology Corporation. Report No.: EM-E960238 2. GENERAL INFORMATION 2.1. Description of Device (EUT) Description : LCD Monit
Page 80 of126 Audix Technology Corporation. Report No.: EM-E960238 8. RF FIELD STRENGTH IMMUNITY TEST 8.1. Test Equipment 8.1.1. For 80MHz ~ 1000MH
Page 81 of126 Audix Technology Corporation. Report No.: EM-E960238 8.2.2. R/S Test Setup 8.3. Test Standard EN 60601-1-2/2001+A1/20
Page 82 of126 Audix Technology Corporation. Report No.: EM-E960238 8.7. Test Procedure The field sensor is placed on the EUT table (0.8 meter above
Page 83 of126 Audix Technology Corporation. Report No.: EM-E960238 RF Field Strength Immunity Test Results AUDIX TECHNOLOGY CORPORATION Date:09/03/2
Page 84 of126 Audix Technology Corporation. Report No.: EM-E960238 9. ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST 9.1. Test Equipment Item Type
Page 85 of126 Audix Technology Corporation. Report No.: EM-E960238 9.7. Test Procedure The EUT and its simulators and all cables were placed 0.1m hi
Page 86 of126 Audix Technology Corporation. Report No.: EM-E960238 Electrical Fast Transient/Burst Immunity Test Results AUDIX TECHNOLOGY CORPORATION
Page 87 of126 Audix Technology Corporation. Report No.: EM-E960238 10. SURGE IMMUNITY TEST 10.1. Test Equipment Item Type Manufacturer Model No.
Page 88 of126 Audix Technology Corporation. Report No.: EM-E960238 10.7. Test Procedure 10.7.1. Set up the EUT and test generator as shown on section
Page 89 of126 Audix Technology Corporation. Report No.: EM-E960238 Surge Immunity Test Results AUDIX TECHNOLOGY CORPORATION Date:09/03/2007 Applica
Page 9 of126 Audix Technology Corporation. Report No.: EM-E960238 Date of Receipt of Sample : Aug. 20, 2007 Date of Test : Aug. 22 ~ 29, 2007 2
Page 90 of126 Audix Technology Corporation. Report No.: EM-E960238 11. CONDUCTED DISTURBANCE IMMUNITY TEST 11.1. Test Equipment Item Type Manufactu
Page 91 of126 Audix Technology Corporation. Report No.: EM-E960238 11.3. Test Standard EN 60601-1-2/2001+A1/2006 (IEC 61000-4-6/2006) 11.4. Severity
Page 92 of126 Audix Technology Corporation. Report No.: EM-E960238 ** For Telecommunication Port ** 11.7.8. Set up the EUT, EM Injection Clamp and
Page 93 of126 Audix Technology Corporation. Report No.: EM-E960238 Conducted Disturbance Immunity Test Results AUDIX TECHNOLOGY CORPORATION Date:09/
Page 94 of126 Audix Technology Corporation. Report No.: EM-E960238 12. POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST 12.1. Test Equipment Item Type
Page 95 of126 Audix Technology Corporation. Report No.: EM-E960238 12.7. Test Procedure The EUT placed on 1m high table that above the ground referen
Page 96 of126 Audix Technology Corporation. Report No.: EM-E960238 Power Frequency Magnetic Field Immunity Test Results AUDIX TECHNOLOGY CORPORATION
Page 97 of126 Audix Technology Corporation. Report No.: EM-E960238 13. VOLTAGE DIPS AND INTERRUPTIONS IMMUNITY TEST 13.1. Test Equipment Item Type
Page 98 of126 Audix Technology Corporation. Report No.: EM-E960238 13.4.2. Equipment and systems are allowed a deviation from the requirements of E
Page 99 of126 Audix Technology Corporation. Report No.: EM-E960238 13.8. Test Results PASSED. Two kinds of EUT with following test modes were perform
Commentaires sur ces manuels